inquiry
Deixe um recado
Se você estiver interessado em nossos produtos e quiser saber mais detalhes, deixe uma mensagem aqui e responderemos o mais breve possível.
Enviar
Tecnologia de proteção de soldagem Bengbu Longkai Co., Ltd.
Lar

respirador motorizado

respirador motorizado

  • Demolition Work: Choosing the Right PAPR
    Demolition Work: Choosing the Right PAPR
    Jan 20, 2026
      Demolition work involves complex and variable environments. From breaking down walls of old buildings to dismantling industrial facilities, pollutants such as dust, harmful gases, and volatile organic compounds (VOCs) are pervasive, placing extremely high demands on respiratory protection for workers. battery powered respirator have become core protective equipment in demolition work due to their advantages of positive pressure protection and low breathing load. However, not all PAPRs are suitable for all scenarios; selecting the right type is essential to build a solid line of defense for respiratory safety. Compared with traditional negative-pressure respirators, PAPRs actively deliver air through an electric fan, which not only reduces breathing fatigue during high-intensity operations but also prevents pollutant leakage through the positive pressure environment inside the mask, significantly improving protection reliability.   For general dust-generating demolition operations, particulate-filtering PAPRs are preferred. Such operations commonly involve the demolition of concrete, masonry, wood, and other components, with respirable dust—especially PM2.5 fine particles—as the primary pollutant. Long-term inhalation can easily induce pneumoconiosis. When selecting a model, high-efficiency particulate filters should be used, and the mask can be chosen based on operational flexibility needs. For open-air scenarios such as ordinary wall breaking and floor demolition, air-fed hood-type PAPRs are more suitable. They do not require a facial fit test, offer strong adaptability, and can also provide head impact protection. For narrow workspaces with extremely high dust concentrations, it is recommended to use tight-fitting full-face PAPRs, which have a minimum air flow rate of no less than 95L/min, forming a tight seal on the face to prevent dust from seeping through gaps.   For demolition operations involving harmful gases, combined-filtering PAPRs are required. During the demolition of old buildings, volatile organic compounds such as formaldehyde and benzene are emitted from paints and coatings, while the dismantling of industrial facilities may leave toxic gases such as ammonia and chlorine. In such cases, a single particulate-filtering PAPR cannot meet protection needs. Dual-filter elements (particulate + gas/vapor) should be used, with precise selection based on pollutant types: activated carbon filter cartridges for organic vapors, and chemical adsorption filter elements for acid gases. For these scenarios, positive-pressure tight-fitting PAPRs are preferred. Combined with forced air supply, they not only effectively filter harmful gases but also reduce pollutant residue inside the mask through continuous air supply, while avoiding poisoning risks caused by mask leakage.   Special scenarios require targeted selection of dedicated loose fitting powered air purifying respirators. Demolishing asbestos-containing components is a high-risk operation—once inhaled, asbestos fibers cause irreversible lung damage. PAPRs complying with asbestos protection standards should be used, paired with high-efficiency HEPA filters. Additionally, hood-type designs must be adopted to avoid fiber leakage due to improper wearing of tight-fitting masks. Meanwhile, the hood should be used with chemical protective clothing to form full-body protection. For demolition in confined spaces such as basements and pipe shafts, oxygen levels must first be tested. If the oxygen concentration is not less than 19% (non-IDLH environment), portable positive-pressure PAPRs can be used with forced ventilation systems. If there is a risk of oxygen deficiency, supplied-air respirators must be used instead of relying on PAPRs.   PAPR selection must balance compliance with standards and operational practicality.  Adjustments should also be made based on labor intensity: most demolition work is moderate to high intensity, so Powered Air Purifying Respirator TH3 are more effective in reducing breathing load, preventing workers from removing protective equipment due to fatigue. Battery life must match operation duration—for long-term outdoor operations, replaceable battery models are recommended to ensure uninterrupted protection. Furthermore, filter elements must be replaced strictly on schedule: gas filter cartridges should be replaced within 6 months of opening, or immediately if odors occur or resistance increases, to avoid protection failure.   Finally, it should be noted that PAPRs are not universal protective equipment, and their use must be based on a comprehensive risk assessment. Before demolition work, on-site testing should be conducted to identify pollutant types, concentrations, and environmental characteristics, followed by selecting the appropriate PAPR type for the scenario.  Only by selecting and using PAPRs correctly can we build a reliable barrier for respiratory health in complex demolition work, balancing operational efficiency and safety protection.If you want know more, please click www.newairsafety.com.
    LEIA MAIS
  • Proteção Respiratória para Soldagem: Respiradores com Purificador de Água Motorizado (PAPR) em 4 Métodos de Soldagem
    Proteção Respiratória para Soldagem: Respiradores com Purificador de Água Motorizado (PAPR) em 4 Métodos de Soldagem
    Oct 25, 2025
    Na soldagem, fumos e gases tóxicos ameaçam a saúde respiratória dos trabalhadores. Como um dispositivo de proteção eficiente, Sistema de respiração com ar motorizado Atuar como uma "barreira respiratória" para diversos cenários de soldagem. Entender como o PAPR se adapta a diferentes métodos de soldagem é fundamental para a segurança. A soldagem a arco com eletrodo revestido (SMAW) produz grandes quantidades de fumos metálicos (por exemplo, óxido de ferro, dióxido de manganês) que causam pneumoconiose. As máscaras tradicionais têm eficácia limitada e alta resistência à respiração. Respirador motorizado usa um ventilador integrado para fornecer ar filtrado, resolvendo problemas de resistência e bloqueando mais de 95% dos vapores finos com cartuchos de filtro de alta eficiência. A soldagem e o corte por arco de plasma geram vapor metálico e ozônio em alta concentração devido às temperaturas extremas. O respirador com purificação de ar (PAPR) oferece "dupla proteção" com filtros específicos para ozônio e filtros de alta eficiência. Seu visor facial de amplo campo de visão também atende às necessidades de precisão das operações com plasma sem comprometer a eficiência. A goivagem a arco de carbono libera poeira de carbono, vapores de óxido de ferro e gases tóxicos (CO, óxidos de nitrogênio). A PAPR utiliza filtros compostos para combater vapores e gases, enquanto sua viseira facial selada impede o vazamento de poluentes, proporcionando proteção abrangente. A soldagem e o corte oxiacetilênicos dependem de gases combustíveis, produzindo gases tóxicos (CO, acetileno) que se acumulam em áreas mal ventiladas. Respirador com suprimento de ar motorizado é equipado com recipientes de vapor orgânico para absorver gases nocivos, e seu sistema de pressão positiva bloqueia poluentes externos, mesmo em espaços fechados. Da soldagem por arco submerso (SMAW) ao corte por oxicorte, o PAPR adapta-se a diversas características de poluentes por meio de filtragem flexível, fornecimento de ar ativo e proteção selada. A escolha do PAPR correto protege a saúde dos trabalhadores e aumenta a segurança operacional. Para saber mais, entre em contato conosco. www.newairsafety.com.
    LEIA MAIS

Deixe um recado

Deixe um recado
Se você estiver interessado em nossos produtos e quiser saber mais detalhes, deixe uma mensagem aqui e responderemos o mais breve possível.
Enviar
CONTATE-NOS: sales@txhyfh.com

Lar

Produtos

Whatsapp

Contate-nos